R-410A PT Chart
Saturation pressure for R-410A from -38°F to 150°F, with liquid (bubble) and vapor (dew) columns. Look up a pressure or temperature, switch to metric, and check typical operating pressures.
By BrazeJobs Team · Updated
R-410A Lookup
Liquid (Bubble)
118.8 psig
Vapor (Dew)
118.4 psig
Bubble Point
39.6°F
Dew Point
39.8°F
Chart range: -38°F to 150°F. Enter vacuum as a negative pressure. Check R-410A superheat and subcooling
R-410A PT Chart
| Temp | Liquid (Bubble) | Vapor (Dew) |
|---|---|---|
| -38°F | 12.1 psig | 12.0 psig |
| -36°F | 13.4 psig | 13.3 psig |
| -34°F | 14.8 psig | 14.7 psig |
| -32°F | 16.3 psig | 16.2 psig |
| -30°F | 17.8 psig | 17.7 psig |
| -28°F | 19.4 psig | 19.3 psig |
| -26°F | 21.0 psig | 20.9 psig |
| -24°F | 22.7 psig | 22.6 psig |
| -22°F | 24.5 psig | 24.4 psig |
| -20°F | 26.3 psig | 26.2 psig |
| -18°F | 28.2 psig | 28.1 psig |
| -16°F | 30.2 psig | 30.0 psig |
| -14°F | 32.2 psig | 32.0 psig |
| -12°F | 34.3 psig | 34.1 psig |
| -10°F | 36.5 psig | 36.3 psig |
| -8°F | 38.7 psig | 38.5 psig |
| -6°F | 41.0 psig | 40.8 psig |
| -4°F | 43.4 psig | 43.2 psig |
| -2°F | 45.9 psig | 45.7 psig |
| 0°F | 48.4 psig | 48.2 psig |
| 2°F | 51.1 psig | 50.8 psig |
| 4°F | 53.8 psig | 53.5 psig |
| 6°F | 56.6 psig | 56.3 psig |
| 8°F | 59.5 psig | 59.2 psig |
| 10°F | 62.4 psig | 62.2 psig |
| 12°F | 65.5 psig | 65.2 psig |
| 14°F | 68.6 psig | 68.4 psig |
| 16°F | 71.9 psig | 71.6 psig |
| 18°F | 75.2 psig | 74.9 psig |
| 20°F | 78.7 psig | 78.4 psig |
| 22°F | 82.2 psig | 81.9 psig |
| 24°F | 85.8 psig | 85.5 psig |
| 26°F | 89.6 psig | 89.2 psig |
| 28°F | 93.4 psig | 93.1 psig |
| 30°F | 97.4 psig | 97.0 psig |
| 32°F | 101.4 psig | 101.1 psig |
| 34°F | 105.6 psig | 105.2 psig |
| 36°F | 109.9 psig | 109.5 psig |
| 38°F | 114.3 psig | 113.9 psig |
| 40°F | 118.8 psig | 118.4 psig |
| 42°F | 123.4 psig | 123.0 psig |
| 44°F | 128.2 psig | 127.7 psig |
| 46°F | 133.0 psig | 132.6 psig |
| 48°F | 138.0 psig | 137.5 psig |
| 50°F | 143.2 psig | 142.6 psig |
| 52°F | 148.4 psig | 147.9 psig |
| 54°F | 153.8 psig | 153.2 psig |
| 56°F | 159.3 psig | 158.7 psig |
| 58°F | 164.9 psig | 164.4 psig |
| 60°F | 170.7 psig | 170.1 psig |
| 62°F | 176.7 psig | 176.0 psig |
| 64°F | 182.7 psig | 182.1 psig |
| 66°F | 188.9 psig | 188.3 psig |
| 68°F | 195.3 psig | 194.6 psig |
| 70°F | 201.8 psig | 201.1 psig |
| 72°F | 208.4 psig | 207.7 psig |
| 74°F | 215.2 psig | 214.5 psig |
| 76°F | 222.2 psig | 221.4 psig |
| 78°F | 229.3 psig | 228.5 psig |
| 80°F | 236.5 psig | 235.8 psig |
| 82°F | 244.0 psig | 243.2 psig |
| 84°F | 251.6 psig | 250.7 psig |
| 86°F | 259.3 psig | 258.5 psig |
| 88°F | 267.3 psig | 266.4 psig |
| 90°F | 275.4 psig | 274.5 psig |
| 92°F | 283.6 psig | 282.7 psig |
| 94°F | 292.1 psig | 291.2 psig |
| 96°F | 300.7 psig | 299.8 psig |
| 98°F | 309.5 psig | 308.6 psig |
| 100°F | 318.6 psig | 317.6 psig |
| 105°F | 341.9 psig | 340.9 psig |
| 110°F | 366.4 psig | 365.4 psig |
| 115°F | 392.3 psig | 391.2 psig |
| 120°F | 419.4 psig | 418.3 psig |
| 125°F | 447.9 psig | 446.8 psig |
| 130°F | 477.9 psig | 476.8 psig |
| 135°F | 509.4 psig | 508.3 psig |
| 140°F | 542.5 psig | 541.4 psig |
| 145°F | 577.3 psig | 576.3 psig |
| 150°F | 613.9 psig | 613.0 psig |
About R-410A
R-410A is an HFC blend of R-32 and R-125 that replaced R-22 in US residential and light commercial AC and heat pumps. It contains no chlorine, so it does not deplete ozone, but its global warming potential is high.
It is a near-azeotropic blend: the glide is a fraction of a degree, so liquid and vapor pressures are almost the same. R-410A runs at about 70% higher pressure than R-22, so its gauges, hoses and components are rated for the higher pressure.
- Residential split AC and heat pumps built from the 2000s through 2024
- Ductless mini-splits and packaged units
- Light commercial rooftop units and VRF systems
R-410A Properties
Key facts for identifying R-410A and choosing tools, oil and replacements.
| Property | Value |
|---|---|
| Type | HFC |
| Composition | R-32 50%, R-125 50% by weight |
| ASHRAE safety class | A1 |
| GWP (IPCC AR4) | 2,088 |
| Boiling point at 1 atm | -61°F |
| Critical temperature | 158.3°F |
| Oil | POE (polyolester) |
| Trade names | Puron, Genetron AZ-20, Suva 410A, Forane 410A |
| Replaces | R-22 |
| Replaced by | R-454B, R-32 |
Typical R-410A Operating Pressures
Suction pressure is the vapor (dew) pressure at the evaporator temperature; head pressure is the liquid (bubble) pressure at the condensing temperature. The temperatures are common design points, not charging targets.
| Condition | Evaporator | Suction | Condensing | Head |
|---|---|---|---|---|
| AC cooling, 95°F outdoor | 40°F | 118.4 psig | 115°F | 392.3 psig |
How to Read the R-410A PT Chart
The chart covers -38°F to 150°F. Pressures are gauge pressure (psig), the number your manifold shows; switch to °C and kPa above if you work in metric.
R-410A is a zeotropic blend, so it boils over a range of temperatures instead of at one point. That range is the glide. The liquid (bubble) column gives the pressure where the first bubble forms; the vapor (dew) column gives the pressure where the last drop of liquid boils off.
At 40°F, the bubble pressure is 118.8 psig and the dew pressure is 118.4 psig. Read the other way, at 118.4 psig the glide is about 0.2°F.
Use the vapor (dew) column for superheat on the suction line and the liquid (bubble) column for subcooling on the liquid line. Mixing them up shifts the answer by the glide.
Superheat and Subcooling Formulas
The PT chart turns a gauge pressure into a saturation temperature. Compare that with a line temperature to get superheat or subcooling.
- Tsuction
- Suction line temperature near the outdoor unit or compressor, °F
- Tliquid
- Liquid line temperature leaving the condenser, °F
- Tdew
- Dew point at suction pressure (vapor column), °F
- Tbubble
- Bubble point at liquid pressure (liquid column), °F
Gauge pressure (psig) is pressure above atmospheric. Below 0 psig, the chart shows vacuum in inches of mercury.
Worked Example: R-410A Superheat and Subcooling
AC cooling, 95°F outdoor: an R-410A system reads 118.4 psig suction with a 50°F suction line, and 392.3 psig on the liquid line with a 105°F liquid line.
- Dew point at 118.4 psig: 40.0°F.
- Superheat: 50°F − 40.0°F = 10.0°F.
- Bubble point at 392.3 psig: 115.0°F.
- Subcooling: 115.0°F − 105°F = 10.0°F.
Is R-410A Being Phased Out?
Under EPA’s AIM Act Technology Transitions rule, new residential and light commercial AC and heat pumps moved to refrigerants with a GWP under 700 starting January 1, 2025. That is why new equipment now ships with R-454B or R-32.
Existing R-410A systems can be serviced for their full life, and R-410A stays available for service. A 2026 EPA rule also removed the federal installation deadline for qualifying residential systems built from older components.
R-410A Field Tips
Practical points for working on R-410A systems, from the sources below.
Sources: ABC: EPA’s removal of the R-410A installation deadline, Greenheck: A2L refrigerants after the 2025 EPA transition, ACHR News: Charging refrigeration systems with blended refrigerants